Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Trauma ; (12): 580-584, 2018.
Article in Chinese | WPRIM | ID: wpr-707343

ABSTRACT

Objective To investigate the effects of hemiarthroplasty with different hip prostheses on the prognosis of unstable osteoporotic intertrochanteric fractures in elderly patients.Methods A retrospective case series study was conducted on the clinical data of 556 elderly patients with unstable osteoporotic femoral intertrochanteric fractures treated with hemiarthroplasty from January 2008 to December 2014.There were 142 males and 414 females,aged (83.1 ± 6.9) years (range,75-103 years).The T value of bone mineral density was-3.5--2.5 SD [(-2.8 ± 0.2) SD].There were 306 cases of type A2.2 and 250 cases of type A2.3 according to AO classification.There were 296 cases of cement type and 260 biological type according to prosthesis type.Operation time,blood loss,time for ambulation,Harris hip score,and incidence of perioperative major complications were used to compare the therapeutic outcomes between the two types of prostheses.Results The operation time [(75.5 ±9.2) minutes],blood loss [(992.9 ± 94.2)ml],and time for ambulation[(7.1 ± 1.8) days] in cement type group were all less than those [(86.1 ± 9.3) minutes,(1 139.5 ± 96.0) ml,and (8.6 ± 2.1) days]in biological type group,but the lung infection rate (19.9%),incidence of cardio-cerebrovascular complications (15.9%) and total death rate (7.1%) in cement type group were significantly greater than the those (13.5%,8.8% and 1.9%) in biological type group (P < 0.05).There was nosignificant difference in Harris score (73.6% vs.82.7%) between the two groups (P > 0.05).Conclusions In the treatment of unstable osteoporotic intertrochanteric fractures in elderly patients by hemiarthroplasty,the use of cement type prosthesis can reduce operation time,blood loss and bed rest time,but it will lead to significant increases of cardio-cerebrovascular complication and overall mortality.The prosthesis type has no significant effect on the improvement of hip function.

2.
Journal of Chongqing Medical University ; (12)1987.
Article in Chinese | WPRIM | ID: wpr-579173

ABSTRACT

Objective:To investigate the effects of magnetic nano-particles on the therapeutics efficacy of high intensity focused ultrasound(HIFU).Methods:The magnetic nano-particles with diameter of 80~90 nm and 200~300 nm were distributed into the egg white phantom respectively.At the same HIFU exposure dose,the length and width of the maximum cross section of the lesions were measured.Results:The results showed that the magnetic nano-particles with diameter of 200~300 nm can enhance the therapeutic efficacy of HIFU,and the areas of lesions were about 2 times larger than those of control group(P0.01).Conclusion:The magnetic nano-particles with diameter of 200~300 nm can change the acoustics environment of egg white phantom and enhance the therapeutic efficacy of HIFU.

SELECTION OF CITATIONS
SEARCH DETAIL